70V and 100V speaker line loss: how to size the cable

On a constant-voltage speaker line, aim to lose no more than 0.5 dB in the cable. That is about 11% of the amplifier’s power. Many manufacturers accept up to 1 dB (about 20%); 0.5 dB is the stricter target. Checking a run takes three numbers: the total tap power, the run length and the cable’s resistance.

Why 70V and 100V lines lose less than 8-ohm runs

Power is voltage times current. Sending the same power at 100V instead of a few volts means far less current, and cable loss depends on current. That is why a paging line can run hundreds of metres to dozens of ceiling speakers, while a low-impedance 8-ohm speaker struggles beyond a few tens of metres on the same cable.

Step 1: turn the tap settings into a load impedance

Add up the transformer tap of every speaker on the line. The line then looks to the amplifier like a single load:

Zload = Vline2 ÷ Ptaps

Ten speakers tapped at 15 W on a 100V line is 150 W, so the load is 100² ÷ 150 = 66.7 ohms.

Step 2: work out the cable’s loop resistance

Current goes out on one conductor and back on the other, so double the run length:

Rcable = 2 × L × r

L is the run length and r is the resistance of one conductor per metre. Maximum resistance per conductor at 20 °C (IEC 60228 for metric sizes):

CableResistance per conductor
1.5 mm²12.1 Ω/km solid or stranded · 13.3 Ω/km flexible
2.5 mm²7.41 Ω/km · 7.98 Ω/km flexible
4 mm²4.61 Ω/km · 4.95 Ω/km flexible
18 AWGabout 20.9 Ω/km
16 AWGabout 13.2 Ω/km
14 AWGabout 8.3 Ω/km
12 AWGabout 5.2 Ω/km

100 m of 1.5 mm² cable is 2 × 100 × 0.0121 = 2.42 ohms with solid or stranded conductors, or 2.66 ohms with flexible speaker cable.

Step 3: convert to decibels

The cable and the load form a voltage divider. The loss at the far end is:

Loss (dB) = 20 × log10( Zload ÷ (Zload + Rcable) )

For the example: 20 × log10(66.7 ÷ 69.1) = −0.31 dB. The last speaker sees about 96.5 V instead of 100 V, comfortably inside a 0.5 dB budget.

Worked example: the same load on different runs

All rows carry the same 150 W of taps and use solid-conductor resistance. With flexible cable the losses are about 10% higher (the 250 m, 1.5 mm² row becomes −0.83 dB). “70V” means 70.7 V.

SystemRunCableLoss
100V100 m1.5 mm²−0.31 dB
100V250 m1.5 mm²−0.75 dB (over budget)
100V250 m2.5 mm²−0.47 dB
70V100 m1.5 mm²−0.61 dB (over budget)
8-ohm direct100 m1.5 mm²−2.30 dB

Two patterns are worth remembering. A 70V line has half the load impedance of a 100V line for the same taps, so it needs roughly twice the copper for the same loss. And a long run usually needs a heavier gauge or a split into two lines, not a bigger amplifier.

What this simple method leaves out

  • It is a worst case. It treats every speaker as if it sits at the far end. Speakers spread along the run lose less, so a run that passes here will pass in reality.
  • Transformers have their own losses. Each speaker’s tap transformer adds insertion loss; check the datasheet.
  • Temperature raises resistance. Copper’s resistance rises about 0.4% per °C, which matters in hot ceiling voids and risers.

Let the software keep track

Redoing this for every line, every time a tap or a route changes, is where spreadsheet mistakes creep in. Nexera calculates Ohm and Volt line loss as you route each cable and warns you when a run goes over budget, so you can change the gauge or split the line before it reaches the cable schedule.